Established in 1997, ESS ELL CABLES CO. Started its operation at Daman (UT) to serve the Indian electrical industry with installed capacity of around 3000 MTof copper / aluminium Wires and Strips per annum.

As the name says, submersible motors are made to function under water (or other fluid) and the winding wires used in them accordingly require high quality insulation which is completely impervious to liquids of anykind.O

ESS ELL winding wires are specially designed to meet the requirements of this application. They have proven their durability and reliability over a decade and ensure trouble-free operation and longer motor life.

ESS ELL winding wires consist of a solid bare copper conductor insulated by means of a plastic sheath made of PVC and Multilayered Polyester and Polypropylene films

Single Coated PVC Insulated Winding Wire

PVC insulated winding wires are manufactured as per IS standards and are accredited with prestigious ISI mark.

Range: 0.50 mm to 3.00 mm

Specification: IS 8783 Part 4/Section 1 : 1995

Double Coated PVC Insulated Winding Wire

Double coated PVC insulated winding wires are also manufactured without increasing the overall diameter of the wire or thickness of insulation. The two layers of PVC are divided into 45:55 proportion of the total thickness of insulation. Double coated PVC insulated winding wires has an upper edge technically over single coated wires

Range: 0.50 mm to 3.00 mm

Multilayered Polyester and Polypropylene Films Wrapped Winding Wire

Poly wrapped winding wires are insulated with high quality polyester and bi-axially oriented polypropylene films. The conductor is covered uniformly by these films with the latest machineries. These wires have excellent electrical, mechanical, thermal and chemical properties and are manufactured as per IS standards.

Range: 0.50 mm to 3.00 mm

Specification: IS 8783 Part 4/Section 3     1995

Sr. Weight (in mm) Diameter Coated Wire (mm) Normal Weight in No. in PVC Diameter(mm) Tolerance Conductor Double 0HMSK.M. at20°C Normal Conductor Minimum-% Elongation Resistance in Overall Size at Break Wrapped Diameter Weight in (in mm) Overall K.G./K.M Size Poly insulated
1. 0.600 0.006 60.98 27 1.00 3.170 1.15 3.500 3.500
2. 0.700 0.007 43.55 28 1.05 4.140 1.35 4.900 4.800
3. 0.800 0.008 34.30 28 1.15 5.200 1.45 6.000 5.900
4. 0.900 0.009 27.10 29 1.30 6.800 1.55 7.400 7.300
5. 1.000 0.010 21.95 30 1.40 8.000 1.55 8.900 8.800
6. 1.100 0.011 17.50 30 1.50 9.500 1.75 10.500 10.400
7. 1.200 0.012 15.26 31 1.60 11.100 1.85 12.300 12.100
8. 1.300 0.013 12.58 32 1.70 13.000 1.95 14.300 14.000
9. 1.400 0.014 11.20 32 1.90 15.500 2.15 16.650 16.400
10. 1.500 0.015 9.75 32 2.00 17.800 2.25 18.900 18.700
11. 1.600 0.016 8.57 32 2.10 19.020 2.35 21.200 21.000
12. 1.700 0.017 7.59 33 2.20 22.300 2.45 23.650 23.400
13. 1.800 0.018 6.77 33 2.30 25.000 2.55 26.300 26.000
14. 1.900 0.019 6.08 33 2.40 27.970 2.65 29.000 28.600
15. 2.000 0.020 5.48 33 2.50 30.800 2.95 32.600 32.100
16. 2.100 0.021 4.97 33 2.60 33.870 3.05 36.300 36.000
17. 2.200 0.022 4.53 33 2.70 36.980 3.15 39.500 39.000
18. 2.300 0.023 4.14 33 2.80 40.230 3.25 42.900 42.300
19. 2.400 0.024 3.81 34 2.90 43.620 3.45 47.000 46.500
20. 2.500 0.025 3.51 34 3.00 47.150 3.55 50.000 49.600